R value is a measure of insulation s ability to resist heat traveling through it.
Spray foam r value required on attic.
Focusing on spray foam insulation materials there is a difference between the two main types.
According to industry publication fine home building the r value for open cell spray foam is between r 3 5 r 3 6 per inch.
When determining how much insulation you need don t guesstimate calculate.
When calculating the r value of a multilayered installation add the r values of the individual layers.
Installing more insulation in your home increases the r value and the resistance to heat flow.
That means if you used foam it green closed cell which is r 7 per inch it s r value for a 3 5 deep wall cavity would be r 24 5.
Know exactly how much you need with our project calculators.
The r value of some insulations also depends on temperature aging and moisture accumulation.
Since closed cell foam has a higher r value per inch installers generally spray 2 in walls and 3 in rooflines to meet the energy code requirements of r 13 and r 19 respectively.
It has a lower r value per inch than closed cell foam and is vapor permeable.
The higher the r value the greater the insulation performance.
Normally in occupied areas all spray foam must be covered by a 15 minute thermal barrier such as thick drywall per code requirements in irc section 316 4 and ibc section 2603 4.
Recommended home insulation r values.
Closed cell spray foam insulation.
A typical 2 4 stud filled with open cell spray foam will have an r value between 10 5 and 14.
The r value of spray foam insulation is approximately 6 per inch so those using spray foam as their insulator will need about 6 3 inches of thickness to reach r 38.
The higher the r value the better the thermal performance of the insulation.
However there are open cell spray foam insulation products actually offer r 3 7 per inch such as icynene classic and.
R values are additive so you can multiple the number of inches of insulation thickness times the r value to arrive at a total insulation value.
Insulation level are specified by r value.
This is very important in situations where your code requires an r 21 for the wall but you only have a 2 4 stud because closed cell spray foam is the only way you would achieve the required r value to meet code.
The r value is r 3 5 to r 3 6 per inch so filling a 2 4 cavity yields about an r 13.
The r value of fiberglass insulation is approximately 2 2 per inch so much thicker fiberglass insulation is required to achieve the same r value of 38.
Closed cell spray foam has a far better r value per inch than other less effective insulations like cellulose fiberglass or even open cell foam.